【廣告】
混流泵
水泵的傳動方式
我廠生產的HW型系列混流泵均可用柴油機、電機帶動,其傳動方式視各地區(qū)動力情況而定,訂貨時根據原動機的型號(功率、轉速)確定水泵的傳動方式,以確定皮帶輪的大小或聯軸器的規(guī)格。
IV. Drive Mode of Pump
Our HW
seriel mixed-flow pump can be driven by diesel engine and motor.The drive mode
can be chosen according to the local motive power situation. When placing an
order for the pump, we should decide the drive mode of the pump according to
the prime motor type(power, rotate speed) in order to confirm the size of
pulley or coupling.
Failure Casues and Resolving Methods
故障現象
Failures
原 因
Reas
消 除
方 法
Methods
1、水泵不出水
No water are
runing out
1、引水不夠真空泵抽吸空氣不盡
2、進水管路進氣
3、水泵轉速太低
4、吸程太高
5、水泵轉向不對
6、輸水高度超過規(guī)定
1.The diversion is not engouth or the
vacuum pump does not remove all air
2.Air suction for inlet pipes
3.The rotate speed of pump is too low
4.Suction head is too high
5.The turnning direction is not right
6.Water delivery height exceeds stated
one.
1、繼續(xù)加灌或抽氣
2、檢查并堵塞之
3、用轉速表檢查予以調整
4、降低安裝位置減少吸程
5、改變旋轉方向
6、減少輸水高度
1.Continue filling or removing air
2.Check and seal it
3.Check by tachometer and adjust it
4.Reduce the installation po ition,
reduce the suction head
5.Change the turnning direction
6. Reduce water delivery height
電動機過熱
原因有四。一是電源方面的原因:電壓偏高或偏低,在特定負載下,若電壓變動范圍應在額定值的 10%至-5%之外會造成電動機過熱;電源三相電壓不對稱,電源三相電電壓相間不平衡度超過5%,會引繞組過熱;電氣方面潛水泵電機是機組的主要設備,電機內部磁力不平衡和其它電氣系統(tǒng)的失調,常引起振動和噪音。缺相運行,經驗表明農用電動機被燒毀85%以上是由于缺相運行造成的,應對電動機安裝缺相保護裝置。二是水泵方面的原因:選用動力不配套,小馬拉大車,電動機長時間過載運行,使電動機溫度過高;啟動過于頻繁、定額為短時或斷續(xù)工作制的電動機連續(xù)工作。應限制啟動次數,正確選用熱保護,按電動機上標定的定額使用。三是電動機身的原因:接法錯誤,將△形誤接成Y形,使電動機的溫度迅速升高;定子繞組有相間短路、匝間短路或局部接地,輕時電動機局部過熱,嚴重時絕緣燒壞;鼠籠轉子斷條或存在缺陷,電動機運行1至2小時,鐵芯溫度迅速上升;通風系統(tǒng)發(fā)生故障,應檢查風扇是否損壞,旋轉方向是否正確,通風孔道是否堵塞;